INPUT
- Voltage ......................................... CS75L - AC90~132V(note1)/CS75
- AC170~264V (or DC 240~340V) (note2)
- Current .......................................... 0.9A max.
- Frequency ..................................... 47~440Hz max. (50~60Hz
typ.)
- Efficiency ...................................... 84% typ.
- Inrush current (at cold start) ............ 20A max. @ 110VAC.(CS75L)
/ 40A max. @ 220VAC (CS75)
- Leakage current ............................. 0.5mA max. @ 110VAC (CS75L)
/ 0.75mA max. @220VAC (CS75)
OUTPUT
- Voltage tolerance ........................... ±10%
typ.
- Ripple and noise ............................ 1% max.
- Line regulation ............................... ±1% max.
- Load regulation ............................... ±1% max. @ Output1 / ±1%
max. @ Output2 / ±2% max. @ Output3
- Dynamic load regulation ................. ±3% max.
- Temperature drift ............................ ±1% typ.
- Rising time ..................................... 100ms max.
- Holding time ................................... 17ms min.
PROTECTION CIRCUIT
- Over current protection ..................... Over
105% of rating (Auto-restart)
- Over voltage protection ..................... 115~140% of rating
- Over temperature protection ............... 80°C min. (Latch-up mode)
ELECTRICALLY ISOLATED
- Input - Output ................................... AC 3KV, 1minute, 10mA
/ DC 500V, 100Mohms min.
- Input - FG ........................................ AC 2KV, 1minute, 10mA
/ DC 500V, 100MOhms min.
- Output - FG ...................................... AC 0.5KV, 1minute, 10mA
/ DC 500V, 70MOhms min.
NOTE:
1. For cases where conformance to various safety specs (CE) are required,
input voltage and frequency range will be 100-120VAC, 50/60Hz.
2. For cases where conformance to various safety specs (CE) are required,
input voltage and frequency range will be 200-240VAC, 50/60Hz.
|